رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
71-02-7001-1000
معلومات الجزء
Finished internally with a silver-based, conductive coating which is covered at each end with a conductive, hot-melt adhesive sealant
TXT
وصف:
S Electrical Insulation Sleeving
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-46.0 degrees celsius and 125.0 degrees celsius
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Flame resistant and mildew resistant and water resistant
Main Body Wall Thickness:
0.050 inches after unrestricted recovery
Main Bodylength:
0.990 inches as supplied
Main Bodylength:
1.000 inches after unrestricted recovery
Main Body Small End Inside Diameter:
0.150 inches after unrestricted recovery
Main Body Small End Inside Diameter:
0.610 inches as supplied
Main Body Large End Inside Diameter:
0.310 inches after unrestricted recovery
Main Body Large End Inside Diameter:
0.610 inches as supplied
Distance From Bottom Of Shoulder To Large End Of Main Body:
0.560 inches after unrestricted recovery
Distance From Top Of Shoulder To Small End Of Main Body:
0.270 inches after unrestricted recovery
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Semirigid
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Plastic, polyolefin
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyolefin
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Boot-straight
MRC:
The maximum potential gradient the insulating material can withstand,per unit thickness,without rupture.UKBG
Dielectric Material Voltage Rating Per Unit Thickness:
200.0 volts per military /0.001 inch/