رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
712c-12-pi-113-jb
MRC:
A measurement of the pipe size the item will accommodate.AAAR
Pipe Size Accommodated:
0.25 inches all ends
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
120.0 degrees fahrenheit single response
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
5419-01-543-0158
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
The pressure required to actuate the power driven unit.CQCN
Power Drive Operating Pressure:
Between 20.0 pounds per square inch and 150.0 pounds per square inch
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
150.0 pounds per square inch single response
MRC:
The face to face distance.CWCF
Face To Face Distance:
171.5 millimeters
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Nptf all ends