رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.982 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.000 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
3
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Mechanical
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
25.0 kilohertz operating channel err-100
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
10.0 hertz operating channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
1.000 kilohms 3rd output channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
10.000 kilohms 2nd output channel err-100
MRC:
The total opposition (resistive and reactive) to the flow of alternating current per channel.BHTN
Impedance Rating Per Channel:
3.000 ohms 1st output channel err-100
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
120.000 microseconds 1st output channel err-100
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
120.000 microseconds 2nd output channel err-100
MRC:
The time required for one complete pulse per channel.BHTP
Pulse Duration Per Channel:
400.000 microseconds 3rd output channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive 1st output channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive 2nd output channel err-100
MRC:
An electrical condition determining the direction in which current tends to flow per channel.BHTS
Polarity Per Channel:
Positive 3rd output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
0.000 pulses per second 1st output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
0.000 pulses per second 2nd output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
0.000 pulses per second 3rd output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
6.000 pulses per second 1st output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
6.000 pulses per second 2nd output channel err-100
MRC:
The average rate at which the pulse(s) recurs within a specific time interval per channel.BHTT
Pulse Repetition Rate Per Channel:
6.000 pulses per second 3rd output channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
0.350 volts 2nd output channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
12.000 volts 3rd output channel err-100
MRC:
The maximum absolute peak value of the pulse per channel.BHTW
Pulse Peak Amplitude Per Channel:
3.500 volts 1st output channel err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
1st output channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
2nd output channel pulse err-100
MRC:
Indicates the type of signal data per channel.BHTZ
Signal Data Type Per Channel:
3rd output channel pulse err-100
MRC:
The limits of calbration,expressed in percent.BJBH
Calibrated Tolerance In Percent:
-10.0/+10.0
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Rectangular
MRC:
A designation of the function which is calibrated.BJBS
Calibration Function:
Frequency
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
15.0 single voltage err-100
MRC:
The value(s) of the potential supplied from an exterior direct current source to operate the item,expressed in volts.BKFB
External Dc Operating Voltage In Volts:
-15.0 single voltage err-100
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Test set subassembly, electrical, except specially designed