رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Electronic Chopper
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Pin
MRC:
The provision/s/ for mounting the item.ABDR
Mounting Provision:
Terminals
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 1.219 inches and 1.281 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 2.719 inches and 2.781 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 0.969 inches and 1.031 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+100.0 degrees celsius
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.AFJK
Cubic Measure:
3.672 cubic inches
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Single pole, double throw
MRC:
Indicates the type of unit.APQB
Unit Type:
Electromechanical
MRC:
Indicates the type of base furnished with the item.AWET
Base Type:
Standard base
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal
MRC:
An indication of whether or not a hermetically sealed feature is provided.AXNN
Hermetically Sealed Feature:
Not provided
MRC:
An indication of whether the drive voltage is the same as,or different from,the input voltage.BGRB
Drive Voltage Relationship To Input Voltage:
Unequal
MRC:
The value,or range of values,for which the drive is rated.BGRC
Drive Voltage Rating:
6.3 ac pounds per hour wet
MRC:
The number of complete cyclic changes,per unit of time,for which the drive is rated.BGRG
Drive Frequency Rating:
60.0 hertz
MRC:
An indication of whether the item is designed to actuate /make/ a contact before or after the preceding contact deactuates /breaks/.BGRK
Contact Operation Sequence:
Breaks before makes
MRC:
The value,or range of values,for which the contact is rated.BGRL
Contact Voltage Rating:
10.0 dc pounds per hour wet
MRC:
The amount of current for which the contact is rated.BGRM
Contact Current Rating:
1.0 milliamperes
MRC:
The difference in phase between two alternating quantities having the same frequency,expressed in degrees.BGRN
Phase Angle In Deg:
18.0
MRC:
That portion of each driving cycle during which electrical continuity exists between the center contact and one stationary contact,expressed in degrees.BGRP
Dwell Time Rating In Deg:
Between 159.0 and 187.0
MRC:
An indication of whether or not a feature for plug in mounting is provided.BGRS
Plug In Mounting Feature:
Provided
MRC:
The size designation of the mounting base as it is commercially known and/or identified.BGRT
Base Mounting Size Designation:
Noval tube base size
MRC:
Indicates the connection location.BGRY
Connection Location:
Top