رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Go, no go indicator used instead of meters, includes an intercommunications capability between two operators when an/arc-109 and / / system is separated, operational temp range is m40 degrees c to p55 degrees c, resistant to salt atmosphere in both oper and non-oper condition, drip-proof case, capable of operating in an explosive atmosphere9002a2
MRC:
A measurement taken at right angles to the length of an item,in distinction from thickness.ABGL
Width:
13.875 inches
MRC:
A measurement of the longest dimension of any object,in distinction from width.ABRY
Length:
12.875 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
115.0 volts
MRC:
The value,or range of values,of direct current potential for which the item is rated.ACYR
Dc Voltage Rating:
28.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz
MRC:
A linear measurement from the surface to a specified inner point on an item,in distinction from height.AEJZ
Depth:
12.000 inches
MRC:
The name assigned to the item by the joint electronics type designation system.AKWA
Joint Electronics Type Designation System Item Name:
Test set, radio
MRC:
The type number assigned to the item by the joint electronics type designation system.AKWB
Joint Electronics Type Designation System Item Type Number:
An/arm-113a
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Alternate operating
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The element,compound,or mixture of which the item is fabricated,excluding any surface treatment,and its location.ANNQ
Material And Location:
Aluminum carrying case
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Single item w/carrying case
MRC:
Indicates the type of test for which the item is designed.AQXY
Test Type For Which Designed:
Ireceiver sensitivity, receiver agc action, receiver audio output, receiver squelch operation, transmitter frequency accuracy, transmitter cw rf foward power output, transmitter modulation /external audio input/, transmitter modulation /internal audio input/, transmitter modulation absence, transmitter sidetone output, transmitter swr, checks for power operation of mode controls, checks for voltage plus 32 vdc, 115vac, 3 phase, 400 hz, qualitative test of volume control
MRC:
The testing functions such as range,sensitivity,output,and the like,for which the item is designed.AQXZ
Operating Test Capability:
Output, rf, 0.1 porm 0.03 v, rms or 15 porm 5 microv, rms at 50 ohms nom impedance in 225 to 399.95 mhz freq range, audio, 0.8 to 0.9 v, rms, open circuit at 1000 hz across 150 ohm load, inputs, audio, 100mw at 150 ohms nom impedance in 300-6000 hz range, rf, 30 watts at 50 ohms nom impedance in 225 to 399.95 freq range
MRC:
The number of alternating current phases.FAAZ
Phase:
Single