رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
79k80260-10-2160
معلومات الجزء
Not for oxygen service media; tube size 0.750 in.
TXT
وصف:
Nonmetallic Hose Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
0.625 inches
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-67.0 degrees fahrenheit single response and 450.0 degrees fahrenheit single response
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the outside circumference.ABKV
Outside Diameter:
0.797 inches
MRC:
The minimum inside bending radius formed without stressing or deformation of a flexible item.ACKH
Minimum Inside Bending Radius:
6.500 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Swivel nut flare 1st end
MRC:
The physical configuration of the outside of the end connection.AKUU
End Connection Design:
Straight 1st end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal tube 1st end
MRC:
The minimum internal pressure rating,determined by destruction tests,at which the item can be expected to rupture.CQBD
Burst Test Pressure:
4000.0 pounds per square inch
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
1000.0 pounds per square inch
MRC:
The angle of the end surface upon which the mated surface seats.CQRB
Seat Angle:
37.0 degrees 1st end
MRC:
The means used and the measurement of the longest dimension of an item.CRXX
Measuring Method And Length:
216.000 inches excluding end fittings
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas single response and hydraulic fluid single response