رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Cam Actuated Fuel Pump
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Nonstandard
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.156 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
8.125 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.062 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Direct cam
MRC:
An indication of whether or not a feature is included for the item to be operated in a specified depth of water without malfunction.AGEB
Fording Feature:
Not included
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Gasket 1
MRC:
A measurement of the longest dimension of the stroke,in distinction from width.AMWL
Stroke Length:
0.250 inches
MRC:
An indication of whether or not a vacuum booster is included.BJJC
Vacuum Booster:
Included
MRC:
Indicates the location of the vacuum booster on the item.BJJD
Err Default:
Err default
MRC:
Indicates the location of the vacuum booster on the item.BJJD
Vacuum Booster Location:
Bottom
MRC:
The required minimum vacuum,expressed in revolutions per minute.BJJF
Err Default:
Err default
MRC:
The required minimum vacuum,expressed in revolutions per minute.BJJF
Minimum Vacuum In Rpm:
8.5 in. Mercury at 1200 rpm
MRC:
An indication of whether or not a fuel filter is included.BJJG
Fuel Filter:
Not included
MRC:
An indication of whether or not a priming lever is included.BJJJ
Priming Lever:
Included
MRC:
The maximum static pressure of the item above the outlet height.BJJK
Maximum Static Pressure Above Outlet Height:
5.25 lb at 16 in. At 1800 rpm
MRC:
The distance from the mounting face of the pump to the center of the actuator.BJJL
Distance From Pump Mounting Face To Actuator Center:
1.750 in. To centerline of cam
MRC:
Indicates the type and size of the inlet connection(s) on the item.BJJM
Inlet Connection Type/size:
Fuel 3/8-18 npsf thd, vacuum 1/8-27 npsf thd
MRC:
Indicates the type and size of the outlet connection(s) on the item.BJJN
Outlet Connection Type/size:
Fuel 3/8-18 npsf thd, vacuum 1/8-27 npsf thd
MRC:
An indication of whether or not a drain facility(ies) is included.BJJP
Drain Facility:
Not included