رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Linear Microcircuit
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
Between 0.335 inches and 0.370 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.260 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-65.0/+150.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Indicator fscm 26055
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Hermetically sealed
MRC:
The chemical compound or mechanical mixture properties of which the inclosure is fabricated.CQSJ
Inclosure Material:
Metal
MRC:
Indicates the physical configuration of the inclosure.CQSZ
Inclosure Configuration:
Can
MRC:
The arrangement or pattern which describes the input circuitry of the item.CQZP
Input Circuit Pattern:
2 input
MRC:
The basic purpose and number of functions of the device,modified by its intended use.CSSL
Design Function And Quantity:
1 regulator, voltage
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated. the treatment is designed to protect the terminal surface(s) and cannot be wiped off.CWSG
Terminal Surface Treatment:
Solder
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
26055-850-007-000 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
10 pin