رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Electrical Dummy Load
MRC:
The amount of coolant necessary to maintain the required operating temperature of the item.AAXT
Cooling System Coolant Flow Rate:
6.0 gallons per minute
MRC:
The total opposition /resistive and reactive/ which the item offers to the flow of an alternating current,expressed in ohms.ACYW
Impedance Rating In Ohms:
50.0
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+0.000/+500.000 kilohertz and +500.000/+700.000 kilohertz and +700.000/+800.000 kilohertz
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.10 and 1.15 and 1.30
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
15.000 kilowatts peak
MRC:
The minimum and maximum values of the frequency range in which the voltage standing wave ratio is specified.AKNK
Voltage Standing Wave Ratio Frequency Range:
+0.000/+500.000 kilohertz and +500.000/+700.000 kilohertz and +700.000/+800.000 kilohertz
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Coaxial line flange
MRC:
The designation or term used to define the nominal size of the coaxial line flange.AKSB
Coaxial Line Flange Size:
5.188 inches
MRC:
The location of the threads on the intake connection.AKSC
Intake Connection Thread Location:
External
MRC:
The location of the threads on a discharge connection.AKSD
Discharge Connection Thread Location:
External
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
All positions
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
3/4-14 npsh
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the intake connection.ASWT
Intake Connection Thread Size And Series/type Designator:
3/4-14 npsh
MRC:
Indicates the type of coaxial line flange provided.AXDC
Coaxial Line Flange Type:
Rigid
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Forced liquid