رقم الجزء 9032239

Electrical Power Cable Assembly

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
9032239
تجريد:
Yes - DEMIL/MLI
صلاحيه:
وحدة القياس:
NIIN:
006281551

معلومات الجزء
2 adapters

NSN
رقم المخزون الوطني:
4935-00-628-1551 4935006281551
TXT
وصف:
Electrical Power Cable Assembly
INC
INC
رمز اسم العنصر:
00485
INC
COM
امتثال:
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Round
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
22.000 feet
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
-65.0 degrees fahrenheit and 160.0 degrees fahrenheit
MRC:
The length of a straight line which passes through the center of a cross section,and terminates at the outside circumference.ADVL
Cross Section Outside Diameter:
0.425 inches
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connector plug both ends all conductors
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
2
MRC:
The number of strands per conductor.BLNZ
Strand Quantity Per Conductor:
19 all conductors
MRC:
The fabricated form of the conductor.CXCW
Conductor Form:
Stranded all conductors
MRC:
The designation used to describe the round stranded or round solid conductor size.CXDC
Round Conductor Size:
16 awg all conductors
MRC:
The american wire gage size of the individual strands of wire used in each stranded conductor.CXDG
Strand Awg Size Per Conductor:
29 all conductors
MRC:
The arrangement and number of arrangements of the conductors.CXDQ
Conductor Arrangement And Quantity:
2 singles
MRC:
The maximum sustained voltage that can be safely applied to the item without risking failure or damage.CXFK
Voltage Rating:
600.0 root mean square (rms) operating voltage all conductors
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
7720480 1st end all conductors
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
8527380 2nd end all conductors
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
18876 1st end all conductors
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
18876 2nd end all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper core conductor all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyamide 1st position jacket cable
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyamide 2nd position jacket all conductors
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyethylene 1st position primary insulation all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
L-p-390, type 2, class l, grade 7 federal specification single material response 1st position primary insulation all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Mil-m-20693 comp a, type 3, grade e military specification single material response 2nd position jacket all conductors
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Mil-m-20693, comp a type 3, grade e military specification single material response 1st position jacket cable
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Qq-w-343, soft federal specification single material response core conductor all conductors
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Tin core conductor all conductors
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Jack and external connector

{lang[cimilar]} Electrical Power Cable Assemblies

« Guided Missile Maintenance, Repair and Checkout Specialized Equipment {lang[catalog]}
قارن الآن»
واضح | أخفى