رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
98403-24-22050
TXT
وصف:
Alternating Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
3.375 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
4.657 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
3.375 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.3120 inches single end
MRC:
The additional parts supplied with the item which may be required for application.AFHR
Accessory Components:
Gear-spur
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise single end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Open
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Induction-squirrel cage and induction-split phase
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 threaded stud
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
0.0220 horsepower output
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
1.813 inches single end
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.781 inches
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
100.0 operating degrees celsius
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.781 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
220.0 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A5 single style single end
MRC:
The number of alternating current phases.FAAZ
Phase:
Single input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 input