رقم الجزء 9T56Y2901

Power Transformer

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
9t56y2901
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
004234227
NSN
رقم المخزون الوطني:
6120-00-423-4227 6120004234227
TXT
وصف:
Power Transformer
INC
INC
رمز اسم العنصر:
32496
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
8.688 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
4.500 inches single mounting facility single center group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
2 primary single component and 2 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
62.5 amperes ac single component all secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
8.3 amperes ac single component all primary
MRC:
The maximum power for which the winding of the item is rated.CRMJ
Winding Power Rating:
1.0 k1lovolt-amperes single component all secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
16.00 ac pounds per hour wet single component all secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
120.00 ac pounds per hour wet single component all primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 screw