رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Video output cable assembly
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
81.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Nsn: 4940-01-471-6396; electronic shop, transportable; w/s patriot missile
MRC:
The number of electrical conductors included on the item.AMQN
Conductor Quantity:
7
MRC:
The number of groups into which two or more conductors are arranged.CXDT
Group Quantity:
1
MRC:
Indicates the type and number of conductor arrangements within groups.CXDY
Conductor Grouping Arrangement Type And Quantity:
6 coaxial first group
MRC:
The identification of the conductors within a group.CXFG
Conductor Sequence Within Groups:
First conductor first group and second conductor first group and third conductor first group and fourth conductor first group and fifth conductor first group and sixth conductor first group
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
7210-1511-000 3rd end second conductor
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
7210-1511-000 4th end third conductor
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
7210-1511-000 5th end fourth conductor
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
7210-1511-000 6th end fifth conductor
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
7210-1511-000 7th end sixth conductor
MRC:
The identifying reference number assigned to the terminal(s) by the manufacturer.CXGG
Terminal Manufacturer Identifying Reference Number:
7210-1511-000 2nd end first conductor
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
19505 2nd end first conductor
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
19505 3rd end second conductor
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
19505 4th end third conductor
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
19505 5th end fourth conductor
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
19505 6th end fifth conductor
MRC:
The five-position commercial and government entity code for the manufacturer of the terminal.CXGN
Terminal Commercial And Government Entity Code:
19505 7th end sixth conductor
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Cabling shall be 50 ohm coax that complies with rg-178; connector 1 shall consist of black thermoplastic housing containging a copper alloy recepticale contact with gold over nickel in mating area and an 18 postion header; connector 8 shall be a 50 ohm bnc plug, nickle plated with gold plated contact; mark assembly as described in diagram
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
All connectors contain gold plated contacts gold
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Gold
MRC:
Test conditions and ratings,or environmental and performance requirements that are different,more critical,or more specific than those specified in a governing test data document.SPCL
Special Test Features:
Test the cable for continuiry, insulation resistance using 500 volt megger between conductors, and bandwidth which shall be greater than 300 mhz