رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Cage: mineral insulated cable
TXT
وصف:
Nonim Electrical Heating Element
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cable, band or tape type
MRC:
The length of that portion of the heating element that imparts heat.ABHS
Effective Heating Length:
1800.000 inches
MRC:
An indication of the radiation spectrum of the element.ABJA
Element Radiation Specificationtrum:
Noninfrared
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Knolls atomic power lab - special project management system
MRC:
The number of elements in the item.BHHK
Element Quantity:
1
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
600.0 ac single voltage
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Cable, 0.3125 in. Dia. With 2 wire conductors; hot section 150 ft. Long; out-and-back circuit with single cold splice connection; cold section 7 ft. Long; 12 in. Pigtail at end of cold section
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Alloy 825 sheath and magnesium oxide insulation sheath
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
power: 88 watts per foot; exposure temperature rating: 1100 deg. F; cable resistance at 68 deg. F: 0.065 ohms/ft