رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
aa591251610tb12
MRC:
The maximum voltage the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration,expressed in volts.AAPB
Dielectric Withstanding Voltage In Volts:
2.2
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Barrier type
MRC:
A measurement of the longest dimension of a mounting slot,in distinction from width.AAQW
Mounting Slot Length:
0.281 inches
MRC:
A measurement taken at right angles to the length of a mounting slot,in distinction from thickness.AAQX
Mounting Slot Width:
0.198 inches
MRC:
The number of terminal rows or terminal provisions included on the item.ABCS
Terminal Row Quantity:
2
MRC:
The center to center distance between terminals.ABCT
Center To Center Distance Between Terminals:
0.375 inches
MRC:
The distance between the terminal row centers.ABCU
Distance Between Terminal Row Centers:
0.688 inches
MRC:
The structural characteristic(s) of the board.ABCX
Board Construction:
Hollow construction without insulated strip
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.875 inches
Distance From Bottom Edge Of Terminal Board To Center Of Mounting Hole:
0.469 inches
Distance From Left Edge Of Terminal Board To Center Of First Mounting Facility:
0.219 inches
Boardlength:
3.375 inches
Boardheight:
0.750 inches
Board Height Excluding Terminals:
0.688 inches
Base Thickness:
0.375 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Ship, ohio class ssn (trident)
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
30.0
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 slot
MRC:
Indicates the type of nonfeedthru terminal furnished with the item.CRNL
Nonfeedthru Terminal Type:
598 single
MRC:
The number of nonfeedthru terminals furnished with the item.CSCS
Nonfeedthru Terminal Quantity:
12 single
MRC:
The arrangement of terminal positions on the item.CWLG
Terminal Pattern Arrangement:
Multi-row
MRC:
The design of the terminal.CWLN
Terminal Design:
Nonfeedthru
MRC:
Markings included on an item for the purpose of offering instructions or warnings or to indicate the purpose,function,or application of the item.excludes manufacturers part numbers,symbols,or the like.MARK
Special Markings:
1 through 12
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy 670 terminals
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic polyester board and glass fiber board
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Mil-m-14, type mai-60 military specification single material response board
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Qq-b728, class b federal specification single material response terminals