رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
act-s128k32c-025p7q
معلومات الجزء
Microcircuit, hybrid, digital, static random access memory, cmos, 128k x 32-bit
TXT
وصف:
Memory Microcircuit
MRC:
The maximum amount of electrical energy that can be expended by an item.AEHX
Maximum Power Dissipation Rating:
2.2 watts
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-65.0/+150.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Nuclear power plants
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Electrostatic sensitive and static operation
MRC:
Indicates the physical configuration of the inclosure.CQSZ
Inclosure Configuration:
Single-in-line
MRC:
The value of the voltage applied and type of specific electrical characteristic for which the item is designed.CZEN
Voltage Rating And Type Per Characteristic:
-0.5 volts input and 7.0 volts input
MRC:
The acceptable time limitation for the item per characteristic.CZEQ
Time Rating Per Chacteristic:
25.00 nanoseconds access
MRC:
Indicates the type of memory device used on the item.CZER
Memory Device Type:
Ram
MRC:
Indicates the type of hybrid technology used in the item.CZES
Hybrid Technology Type:
Monolithic
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Generic p/n 128k32-25h
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
96906-mil-std-883 standard (includes industry or association standards, individual manufactureer standards, etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
66 case