Also generates ramp; triangle; si (x)/x; exponential rise and decay, gaussian, lorentz; haversine; dc; and noise waveforms, amplitude into 50 ohms is 20mv peak/peak to 10v peak/peak; remote programming via gpib/lan/10base-t/100base-tx; usb1.1, option (a0) north america power; option (l0) english manual and front panel overlay
TXT
وصف:
Electronic Te Function Generator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.200 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
6.600 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+50.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Vdats
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Automatic or manual
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Free-standing and top of cabinet/counter
MRC:
Indicates the type of control.AQZF
Control Type:
Local or remote
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The physical configuration of the output wave.BJBJ
Output Wave Shape:
Sine and square and pulse, trigger
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
360.0 2nd voltage and 440.0 2nd voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
47.0 1st voltage and 63.0 1st voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
100.0 1st voltage and 240.0 1st voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
115.0 2nd voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The alpha-numeric designation that identifies the classification of the item according to the category of functions performed.FCLS
Functional Classification:
Bb-1.2