رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Two terms for external voltage and locking coil, two terms for signal coil /total 4/
TXT
وصف:
Meter Movement Relay
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
4
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder lug
MRC:
A measurement taken at right angles to the length of a mounting flange,in distinction from thickness.ADMH
Mounting Flange Width:
2.695 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetically sealed
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Three 0.125 in. Diameter mtg holes spaced 120 degrees apart on 1.220 in. Radius
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
125.0 volts
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main contacts including the number of poles or forms.APDZ
Main Contact Arrangement:
2 pole, single throw, both positions maintained
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Dc
MRC:
The current rating of the main contact/s/.APEC
Main Contact Current Rating:
0.050 amperes
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Dc
MRC:
The amount of voltage required to operate the meter movement,expressed in volts.APGP
Meter Movement Voltage In Volts:
24.000
MRC:
An indication of the minimum and maximum amount of current used in the meter movement.APGR
Meter Movement Current Range:
+0.0/+100.0 microamperes
MRC:
An indication of the specific condition that causes the contacts to close.APMT
Contact Closing Condition:
Increase value
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Provided
MRC:
Indicates the type of lock in device provided.APNS
Lock In Device Type:
Self-holding spring
MRC:
The means by which the item is released.APNT
Release Method:
Electromagnetic
MRC:
A measurement between the mounting flange and the extremity of the meter, indistinction from height.APST
Meter Depth Behind Mounting Flange:
1.405 inches
MRC:
The length of a straight line which passes through the center of the meter body and terminates at the circumference.APTF
Meter Body Diameter:
2.210 inches