رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Synthesized waveshapes are sine, square, triangle, ramp, pulse, arbitrary, & dc; operating modes: continuous, triggered, gated, burst waveform advance, & autostep; programmable interface gpib--ieee-488.2-1987 compatible; current-5 amps; power dissipation-300 watts; recommended adjustment interval--1000 hours or 6 months, whichever occurs first; original name was "generator, arbitrary"
TXT
وصف:
Electronic Te Function Generator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.400 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
14.250 inches
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+5.0/+55.0
MRC:
The amplitude of vibration for which the vibration resistance frequency range applies.AFDN
Vibration Resistance Amplitude:
0.003 inches total excursion
MRC:
The maximum force at impact that the item is rated to withstand,without resulting in any permanent change in physical or electrical characteristics,expressed in gravitational units /g's/.AFDP
Shock Resistance Rating In Gravitational Units:
20.0
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+10.0/+40.0 degrees celsius
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
4600.0 meters
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Top of cabinet/counter
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
0.01 kilohertz operating channel and 250000.00 kilohertz operating channel
MRC:
Indicates the type and number of indicator device(s) included.BJBL
Indicator Device Type And Quantity:
1 cathode ray tube
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
48.0 1st voltage and 63.0 1st voltage
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
48.0 2nd voltage and 63.0 2nd voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
180.0 2nd voltage and 250.0 2nd voltage
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
90.0 1st voltage and 127.0 1st voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single