رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
b-54167-2part20
معلومات الجزء
Weapon system essential
TXT
وصف:
Sensitive Switch
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Corrosion resistant and explosion proof
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
101.6 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
167.5 millimeters
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Metal
Housing Height:
145.0 millimeters
MRC:
A measurement of the longest dimension of the housing,in distinction from width.AFWD
Housing Length:
101.6 millimeters
Center To Center Distance Between Housing Mounting Facilities Parallel To Length:
80.0 millimeters
Center To Center Distance Between Housing Mounting Facilities Parallel To Width:
80.0 millimeters
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
480.0 ac and 250.0 dc
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Ticonderoga class cg (47), cvn 68 class reactor fill auxiliary system, forrestal class cv, spruance class dd (963), supply class aoe, nimitz class cvn, oliver perry class ffg.
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
3 pole, double throw, one position momentary single switch unit
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The movement of the switch actuator.CXQQ
Actuator Movement:
Between 15.0 pretravel degrees and 90.0 overtravel degrees and 10.0 differential degrees
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
250.000 milliamperes resistive dc and 15.000 amperes resistive ac
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
9 screw