Pipe To Tube Tee
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
250.0 degrees fahrenheit single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Plain (pipe) 2nd end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Socket (tube) 1st end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Socket (tube) 3rd end
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
1.328 inches 1st end
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
1.344 inches 2nd end
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
1.375 inches 3rd end and 1.469 inches 3rd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal pipe 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded internal tube 3rd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded internal tube 1st end
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
200.0 pounds per square inch single response
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.750 inches 2nd end
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.875 inches 1st end
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.875 inches 3rd end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.042 inches 1st end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.042 inches 2nd end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.049 inches 3rd end
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy or copper
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Water 1st response
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Fluid 2nd response
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Npt 2nd end