Base temperature rating minus 54 degrees c to 100 degrees c; altitude rating sea level to infinity
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 3.310 inches and 3.430 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 1.470 inches and 1.530 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 2.720 inches and 2.780 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Hermetically sealed
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
24.0 dc volts single operating power rqmt and 30.0 dc volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
59.0 dc volts single power output and 66.0 dc volts single power output
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 single power output
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment single power output
MRC:
The means used to change alternating current voltage to direct current voltage.BHQN
Rectification Method:
Single phase full wave center tap
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Filter
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
160.0 dc milliamperes single power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Top panel single power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Ferrule single power output
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Ferrule single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
2 single operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Convection