رقم الجزء B4000-2

Laboratory Fume Hood

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
b4000-2
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
010371353

معلومات الجزء
Glass view screen, depressed work surface, 8 in. By 48 in. Operator access opening

NSN
رقم المخزون الوطني:
6640-01-037-1353 6640010371353
TXT
وصف:
Laboratory Fume Hood
INC
INC
رمز اسم العنصر:
32709
MRC:
The rated power that an item can safely consume or provide,measured in watts.ABJL
Wattage Rating In Watts:
753.25
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Cock, gas 1; gage, pressure 1; lamp, fluorescent 1; lamp, ultraviolet 1; pan, drain 1; valve, drain 1
MRC:
The element,compound,or mixture of which the basic material is fabricated.AMSP
Basic Material:
Steel and steel, stainless
MRC:
The amount of apparent power,as distinguished from true power,for which the item is rated.AQYE
Volt-ampere Rating:
0.001
MRC:
A measurement of the longest dimension of a table,in distinction from width.ARDQ
Table Length:
23.000 inches
MRC:
A measurement taken at right angles to the length of a table,in distinction from thickness.ARDR
Table Width:
48.000 inches
MRC:
The rated horsepower of the electric motor.ASHK
Electric Motor Horsepower Rating:
0.5
MRC:
The element,compound,or mixture of which the cabinet is fabricated,excluding any surface treatment.AZSB
Cabinet Material:
Steel
MRC:
A measurement form the bottom to the top of a table,in distinction from depth.CLRH
Table Height:
23.000 inches
MRC:
A measurement of the longest dimension of the hood,in distinction from width.CLRS
Hood Length:
50.500 inches
MRC:
A measurement from the bottom to the top of the hood,in distinction from depth.CLRT
Hood Height:
79.000 inches
MRC:
The name and number of heating and/or air circulating unit controls provided.CLRZ
Heating/air Circulating Unit Control Name And Quantity:
Switch, blower 1
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
115.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0

{lang[cimilar]} Laboratory Fume Hoods

« Laboratory Equipment and Supplies {lang[catalog]}
قارن الآن»
واضح | أخفى