رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Dc
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
16.125 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
14.250 inches
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
150 single indicator single range
MRC:
The hue or tint of the dial scale marking(s).APMM
Dial Scale Marking Color:
Black single indicator single range
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-0.1/+0.1 at full scale single indicator single range
MRC:
Indicates the type of movement provided.AQEC
Movement Type:
Moving coil, permanent magnet
MRC:
The hue or tint of the background.AQFY
Background Color:
White single indicator single range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 30.0 milliamperes, dc single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 300.0 milliamperes, dc single indicator 7th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 7.5 milliamperes, dc single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+15.0 milliamperes, dc single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+150.0 milliamperes, dc single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+3.0 milliamperes, dc single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0 to 1500.0 milliamperes, dc single indicator 9th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+75.0 milliamperes, dc single indicator 5th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+750.0 milliamperes, dc single indicator 8th range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Magnetic shield
MRC:
The means employed to suspend the movement of the item.CTQL
Movement Suspension Method:
Jewel pivot base
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
2 binding post
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Wood
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
D1 rectangular or square
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular or square