Signal Generator
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
9.188 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
12.313 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.750 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Enameled
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Project code ' cxc '
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Included
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 1.5 volts and 90.0 volts
MRC:
Indicates the type of modulation provided.AYYE
Modulation Type:
Am
MRC:
The degree of conformity of a measurement to a standard or true value for which the calibration is rated.BDHW
Calibration Accuracy Rating:
Porm 0.02 pct
MRC:
The fixed number of complete cyclic changes,per unit of time,for which the item is rated.BHFW
Fixed Frequency Rating:
75.000 megahertz
MRC:
The number of fixed frequencies provided.BHFX
Fixed Frequency Quantity:
1
MRC:
An indication of whether or not a crystal controlled feature is provided.BHFY
Crystal Controlled Feature:
Provided
MRC:
An indication of the maximum signal output transmitted by the item.BHGB
Maximum Signal Output:
3 v
MRC:
Indicates the location of the modulator on the item.BHGD
Modulator Location:
Internal
MRC:
The number of complete cyclic changes,per unit of time,for which the modulation is rated.BHQD
Modulated Frequency Rating:
400.0 hertz and 3000.0 hertz
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Generator, signal, except specially designed