رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
bhsf-182436-1371
معلومات الجزء
Endothermic; furance shall be initally wired for 230 volts, with all hardware furnished for field conversion to 460 volts; flame curtain is required for flammable atmospheres over 1400 deg. F. Per nfpa 86c
TXT
وصف:
Electric Heat Treating Furnace
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Floor
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
24.000 inches
MRC:
A measurement of the longest inside dimension of an item,in distinction from width.ADJU
Inside Length:
36.000 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
2500.0 degrees fahrenheit
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+1400.0/+2500.0 degrees fahrenheit
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
18.000 inches
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Temperature recorder 1, air operated door 1
MRC:
Indicates the design type of the item.APGF
Design Type:
Controlled atmosphere full muffle oven
MRC:
Indicates the type of temperature control device provided.AZFX
Tempurature Control Device Type:
Automatic
MRC:
The rated power that an item can safely consume or provide,measured in kilowatts.CFSP
Wattage Rating In Kilowatts:
40.0
MRC:
An indication of whether or not a tilting hearth is included.CFSQ
Tilting Hearth:
Not included
MRC:
An indication of whether or not a work holding basket is included.CFSR
Work Holding Basket:
Not included
MRC:
Indicates the location and number of doors and/or openings.CFSS
Door/opening Location And Quantity:
Door in front, 1
MRC:
An indication of whether or not a counterweight(s) is included.CFST
Counterweight:
Not included
MRC:
An indication of whether or not equipment for a flame curtain is included.CFSW
Equipment For Flame Curtain:
Included
MRC:
The means used to operate the access.CGSP
Access Operation Method:
Air operated door with foot operated control valve
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
230.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three