رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
14.000 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Flange
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
11.500 inches
MRC:
Indicates the design type of the item.APGF
Design Type:
Wet
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Water
MRC:
The basic design of the muffler.ARND
Muffler Design:
Directional vane
MRC:
The number of baffles included on the item.ARNE
Baffle Quantity:
2
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
3
MRC:
The physical configuration of the body.ARNG
Body Shape:
Round
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Horizontal
MRC:
The location of the inlet.ARNJ
Inlet Location:
2-1/4 in. C to c from horizontal center line
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
3.000 inches
MRC:
The physical configuration of the inlet flange.ARNL
Inlet Flange Shape:
Round
MRC:
The type and number of inlet flange mounting provisions provided.ARNM
Inlet Flange Mounting Provision And Quantity:
4 holes
MRC:
The length of a straight line passing through the center of an inlet flange mounting hole,and terminating at the circumference.ARNN
Inlet Flange Mounting Hole Diameter:
0.750 inches
MRC:
The spacing of the inlet flange mounting provision.ARNT
Inlet Flange Mounting Provision Spacing:
5-1/2 in. Diameter bolt circle
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Flange
MRC:
The location of the outlet.ARTJ
Outlet Location:
2-5/8 in. C to c from horizontal center line
MRC:
A measurement of the longest dimension of the outlet projection,in distinction from width.ARTK
Outlet Projection Length:
3.000 inches
MRC:
The physical configuration of the outlet flange.ARTL
Outlet Flange Shape:
Round
MRC:
Indicates the type and number of outlet flange mounting provisions provided.ARTM
Outlet Flange Mounting Provision And Quantity:
4 holes
MRC:
The length of a straight line passing through the center of an outlet flange mounting hole,and terminating at the circumference.ARTN
Outlet Flange Mounting Hole Diameter:
0.750 inches
MRC:
A measurement of the spacing of the outlet flange mounting provision.ARTT
Outlet Flange Mounting Provision Spacing:
5-1/2 in. Diameter bolt circle
MRC:
A narrative description of the type of water inlet connection.ARWE
Err Default:
Err default
MRC:
A narrative description of the type of water inlet connection.ARWE
Water Inlet Connection Type:
Threaded
MRC:
The location of the water inlet.ARWF
Err Default:
Err default
MRC:
The location of the water inlet.ARWF
Water Inlet Location:
Directly above exhaust inlet
MRC:
A measurement of the longest dimension of the water inlet projection,in distinction from width.ARWG
Err Default:
Err default
MRC:
A measurement of the longest dimension of the water inlet projection,in distinction from width.ARWG
Water Inlet Projection Length:
1.000 inches
MRC:
Designates the thread diameter and quantity of threads per specific measurement scale.ARWY
Err Default:
Err default
MRC:
Designates the thread diameter and quantity of threads per specific measurement scale.ARWY
Water Inlet Thread Size:
1-11-1/2
MRC:
A designation indicating the diameter-pitch and the number of threads per specific measurement scale applied to a series of specific diameters of a water inlet.ARWZ
Err Default:
Err default
MRC:
A designation indicating the diameter-pitch and the number of threads per specific measurement scale applied to a series of specific diameters of a water inlet.ARWZ
Water Inlet Thread Series Designator:
Npt
MRC:
The direction of the water inlet thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ARXA
Err Default:
Err default
MRC:
The direction of the water inlet thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ARXA
Water Inlet Thread Direction:
Right-hand
MRC:
Indicates the location/s/ of the water inlet on which thread is located.ARXB
Err Default:
Err default
MRC:
Indicates the location/s/ of the water inlet on which thread is located.ARXB
Water Inlet Thread Location:
Internal
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Ceramic enamel
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
B type
MRC:
The variation when the item is in conformity with a type designator covered by a specification or standard,except in regard to one or more technical differentiating characteristics.ZZZX
Departure From Cited Designator:
Acqw, arnj, arnk, arnl, arnm, arnn, arnt, artf, arth, artj, artk, artl, artm, artn, artt, arwc, arwe, arwf, arwg, arwy, arwz, arxa, arxb