رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Variable Attenuator
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Waveguide
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Waveguide type
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.600 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.281 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.125 inches
MRC:
Equal or unequal distances between graduations representing values of measurement on a scale.ABWF
Scale Linearity:
Nonlinear
MRC:
The number of scale divisions.ABWG
Scale Division Quantity:
20
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0/+55.0 degrees celsius
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.15
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
3.0 watts average
MRC:
Indicates the type of waveguide flange.AKPT
Waveguide Flange Type:
Cover
MRC:
The alphabetical characters and numerals which identify the specific waveguide flange type.AKSA
Waveguide Flange Designation:
Ug-344/u
MRC:
The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
Overall Attenuation Range In Decibels:
+0.0/+20.0
MRC:
The frequency at which the attenuation accuracy was measured.ASYE
Attenuation Accuracy Reference Frequency:
6.6 gigahertz
MRC:
The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
Attenuation Variation Method:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 terminal
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 5.850 gigahertz and 8.200 gigahertz
MRC:
The overall limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.BQNR
Overall Attenuation Accuracy In Decibels:
-1.50/+1.50
MRC:
Indicates the type and number of facilities for adjusting the item.CQTQ
Adjustment Device Type And Quantity:
1 knob
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 flange