رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Electrical Receptacle Connector
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2a
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight shape, flange mount, external coupling
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.828 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Between 2.219 inches and 2.281 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Between 2.219 inches and 2.281 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
Between 0.168 inches and 0.178 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.AEBW
Center To Center Distance Between Mounting Facilities Parallel To Height:
Between 1.745 inches and 1.755 inches
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.745 inches and 1.755 inches
MRC:
The length of a straight line which passes through the center of the cable entrance,and terminates at the circumference.AFQJ
Cable Entrance Diameter:
1.708 inches
Distance From Mounting Shoulder To Front Face:
Between 0.875 inches and 0.885 inches
MRC:
Indicates the type of threaded device included on the item.AFQR
Threaded Device Type:
Coupling facility
MRC:
The number of mating ends provided with the item which are designed to accommodate another connector.AFQW
Mating End Quantity:
1
MRC:
The style designation indicating the configuration that most nearly corresponds to the arrangement of the contact position/s/.AFQX
Contact Position Arrangement Style:
32-7 single mating end
MRC:
An indication of whether or not the contact(s) is removable.AFQZ
Contact Removability:
Nonremovable single mating end all contact groupings
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
13.0 single mating end 1st contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
13.0 single mating end 3rd contact grouping
MRC:
The maximum current which the contact may continuously carry without degradation or destruction,expressed in amperes.AFRC
Contact Maximum Current Rating In Amps:
23.0 single mating end 2nd contact grouping
MRC:
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.AFRD
Contact Maximum Ac Voltage Rating In Volts:
200.0 single mating end 1st contact grouping
MRC:
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.AFRD
Contact Maximum Ac Voltage Rating In Volts:
500.0 single mating end 2nd contact grouping
MRC:
The maximum alternating current potential that may be applied continuously to the contact without damage,expressed in volts.AFRD
Contact Maximum Ac Voltage Rating In Volts:
500.0 single mating end 3rd contact grouping
MRC:
The maximum direct current potential that may be applied continuously to the contact without damage,expressed in volts.AFRE
Contact Maximum Dc Voltage Rating In Volts:
250.0 single mating end 1st contact grouping
MRC:
The maximum direct current potential that may be applied continuously to the contact without damage,expressed in volts.AFRE
Contact Maximum Dc Voltage Rating In Volts:
500.0 single mating end 2nd contact grouping
MRC:
The maximum direct current potential that may be applied continuously to the contact without damage,expressed in volts.AFRE
Contact Maximum Dc Voltage Rating In Volts:
700.0 single mating end 3rd contact grouping
MRC:
The means used to prevent mismating or cross plugging of contacts.AFRN
Polarization Method:
Keyway or multiple keyway
MRC:
The amount of clockwise displacement of the indexing radius of the insert from normal position,expressed in degrees.AFRP
Insert Position In Deg:
0.0
MRC:
Indicates the type of shell included on the item.AFRT
Shell Type:
Solid
MRC:
The means used to secure a connector to its mating counterpart.AFRV
Connector Locking Method:
Externally threaded shell
MRC:
The means by which the connector cable is relieved of stress and strain.AFRW
Connector Cable Strain Relief Method:
Potting type
MRC:
A nominal measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AKMG
Thread Length:
0.625 inches
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
18
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
2.000 inches
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Back single mating end all contact groupings
MRC:
The chemical compound or mechanical mixture properties of which the contact is fabricated.CQTZ
Contact Material:
Copper alloy single mating end all contact groupings
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the contact surface(s) and cannot be wiped off.CQYH
Contact Surface Treatment:
Silver single mating end all contact groupings
MRC:
The chemical compound or mechanical mixture properties of which the insert is fabricated.CQZG
Insert Material:
Rubber single mating end
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Solder well single mating end all contact groupings
MRC:
The chemical compound or mechanical mixture properties of which the shell is fabricated.CSPT
Shell Material:
Aluminum alloy
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the shell surface/s/ and cannot be wiped off.CSWM
Shell Surface Treatment:
Cadmium and chromate
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
24 single mating end 3rd contact grouping
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
4 single mating end 1st contact grouping
MRC:
The number of contacts included with the item which provides electrical connection.CXCG
Included Contact Quantity:
7 single mating end 2nd contact grouping
MRC:
Indicates the type of contact(s) included with the item.CXCL
Included Contact Type:
Round pin single mating end all contact groupings
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Contact surfaces silver
MRC:
An indication of the precious material contained in the item,and the amount per a measurement scale.PMWT
Precious Material And Weight:
0.035 silver grains, troy
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Silver
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Uns