رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
cg-03-cv-10
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
011363575

معلومات الجزء
Media hydraulic fluid

NSN
رقم المخزون الوطني:
4820-01-136-3575 4820011363575
TXT
وصف:
Safety Relief Valve
INC
INC
رمز اسم العنصر:
05488
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Piston
MRC:
The rated valve discharge capacity per unit of time.ADSY
Valve Discharge Flow Rate:
8.0 gallons per minute
MRC:
The number of bolt holes provided on the item.AECS
Bolt Hole Quantity:
4 1st end
MRC:
A nominal measurement taken at right angles to the length of an item,in distinction from thickness.AKGF
Width:
3.125 inches 1st end
MRC:
A nominal measurement of the longest dimension of an item,in distinction from width.AKGG
Length:
4.750 inches 1st end
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Manual
MRC:
The physical configuration of the flange.ARKN
Flange Shape:
Rectangular with holes 1st end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Flange 1st end
MRC:
The minimum to maximum pressures at which the item may be set to open.CQCY
Adjustable Pressure Range:
+500.0/+2000.0 pounds per square inch
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
2000.0 pounds per square inch single response
MRC:
A nominal measurement of the smallest dimension of an item,in distinction from length or width.CWCK
Thickness:
1.125 inches 1st end
MRC:
The nominal length of a straight line which passes through the center of the bolt hole,and terminates at the circumference.CWCQ
Bolt Hole Diameter:
0.406 inches 1st end
MRC:
The center to center nominal distance between bolt holes along the length of an item.CWCY
Center To Center Distance Between Bolt Holes Along Length:
4.062 inches all ends
MRC:
The center to center nominal distance between bolt holes along the width of an item.CWDC
Center To Center Distance Between Bolt Holes Along Width:
2.438 inches all ends
MRC:
The design of the flange face.CWDF
Flange Face Design:
Plain 1st end
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090