رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.562 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
3.000 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.812 inches single mounting facility single center group
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.812 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.375 inches
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.169 inches single group
MRC:
Indicates the type of inductance included on the item.ACYF
Inductance Type:
Fixed
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
1.20 millihenries single component all winding
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
2 single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Partially enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket single group and slot single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component all winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
24.0 amperes dc single component all secondary
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.013 single component all winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 tab, solder lug