رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
cm11n01-j20wdl-
TXT
وصف:
Fluid Pressure Regulating Valve
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Hydraulic oil
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal pipe
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
7/8-14 unf
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
Indicates whether or not the third end is identical with first or second end.ACMX
Third End Relationship With Preceding Ends:
Not identical with first or second end
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
3
MRC:
The means other than the end connection/s/ by which the item may be mounted.ADZJ
Mounting Facility:
Bolts
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+500.0/+2500.0 pounds per square inch
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic single stage
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
2500.0 pounds per square inch
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included