رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Plastic Dielectr Fixed Capacitor
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
W/o mtg facilities, axial terminals
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
1.625 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
0.532 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.250 inches
MRC:
A designator indicating a graphic representation,in standard and accepted symbols,of essential electrical-electronic elements and related connections on the item.AEBZ
Schematic Diagram Designator:
No common or grounded electrode (s)
MRC:
Indicates the type of internal electrical connection utilized.AFHW
Internal Electrical Connection Type:
Extended foil
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Hermetically sealed case
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at the maximum operating temperature of the item.CQBF
Insulation Resistance At Maximum Operating Temp:
5000.0 megohm-microfarads
MRC:
The relative level of the quantity of electric charge at a given potential which the capacitor is capable of receiving and storing per section.CQBQ
Capacitance Value Per Section:
0.470 microfarads single section
MRC:
The temperature/s/ at which an item can function without voltage derating.CQJJ
Nonderated Operating Temp:
Between -65.0 degrees celsius and 85.0 degrees celsius
MRC:
The highest value and type of potential that may be continuously applied to the item per section at the highest operating temperature permissible without voltage derating.CQWM
Nonderated Continuous Voltage Rating And Type Per Section:
200.0 dc single section
MRC:
The limits of permissible deviation per section of a measured value from a specified value.CRTP
Tolerance Range Per Section:
-5.00/+5.00 percent single section
MRC:
The chemical compound or mechanical mixture properties of which the case is fabricated.CWJK
Case Material:
Metal
MRC:
Direct current resistance between two conductors that are separated by an insulating material,measured at reference temperature.CWPK
Insulation Resistance At Reference Temp:
100000.0 megohms
MRC:
The ratio of resistance to capacitive reactance measured at reference temperature.CWPM
Dissipation Factor At Reference Tempurature In Percent:
0.6000
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated. the treatment is designed to protect the terminal surface(s) and cannot be wiped off.CWSG
Terminal Surface Treatment:
Solder
MRC:
The kind of insulating medium used to separate the capacitor electrodes.CWSS
Dielectric Material:
Plastic polyethylene terephthalate
MRC:
The chemical compound or mechanical mixture properties of which the case insulation is fabricated.CWSZ
Case Insulation Material:
Plastic
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-c-19978 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 uninsulated wire lead