رقم الجزء CRX-603B-4P

Refrigeration Condenser

الأسعار والتوافر

أرسل هذا النموذج لمعرفة الأسعار الحالية وتوافر NSN هذا.
رقم الجزء:
كم:
عنوان البريد الإلكتروني:
الهاتف:
مرجع:
شركة:
اسم:

نحن لا نشارك أو نبيع معلوماتك لأي شخص.
الخصوصيه | حيث

All major credit cards accepted as well as gov. p-cards
رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
crx-603b-4p
تجريد:
No
صلاحيه:
وحدة القياس:
NIIN:
015505523
NSN
رقم المخزون الوطني:
4130-01-550-5523 4130015505523
TXT
وصف:
Refrigeration Condenser
INC
INC
رمز اسم العنصر:
36880
MRC:
The refrigeration capacity of the item as rated by industry,expressed in tons per hour.AAYE
Refrigeration Flow Rate In Tons Per Hour:
10.000
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
39.562 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
7.500 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water
MRC:
The element,compound,or mixture of which the shell is fabricated.AEUG
Shell Material:
Steel
MRC:
The element,compound,or mixture of which the head is fabricated,excluding any surface treatment.ARGE
Head Material:
Iron
MRC:
The type of water with which the item is designed to be used.AWCD
Water For Which Designed:
Fresh or salt
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Copper
MRC:
The number of water connections provided.AWKT
Water Connection Quantity:
2
MRC:
Indicates the type of water connection/s/.AWKW
Water Connection Type:
Threaded pipe
MRC:
The number of refrigerant inlet connections provided.AWKX
Refrigerant Inlet Connection Quantity:
1
MRC:
Designates the size of the water connection.AWKZ
Water Connection Size:
1-1/4 in.
MRC:
Designates the size of the refrigerant inlet connection.AWLA
Refrigerant Inlet Connection Size:
1.5/8 in.
MRC:
The number of refrigerant outlet connections provided.AWLB
Refrigerant Outlet Connection Quantity:
1
MRC:
Designates the size of the refrigerant outlet connection.AWLD
Refrigerant Outlet Connection Size:
1-1/8 in.
MRC:
The maximum internal pressure,determined by destruction tests at which the item can be expected to rupture.AWWG
Refrigerant Side Test Minimum Pressure:
350.0 pounds per square inch
MRC:
The maximum internal pressure,determined by destruction tests at which the item can be expected to rupture.AWWH
Water Side Test Minimum Pressure:
300.0 pounds per square inch
MRC:
Indicates the type of cooling.AYTS
Cooling Type:
Water

{lang[cimilar]} Refrigeration Condensers

« Refrigeration and Air Conditioning Components {lang[catalog]}
قارن الآن»
واضح | أخفى