رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Temperature and relative humidity probe
TXT
وصف:
Humidity-temperature Probe
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
180.0 millimeters
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-40.0/+70.0 degrees celsius
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
4
MRC:
The recognized shape,configuration,structure,or mold of a substance,natural or refined,that most nearly corresponds to the appearance of the item.AGXW
Physical Form:
Straight
MRC:
Indicates the type of contact(s) included on the item.AKSF
Contact Type:
Pin
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 6.0 volts and 16.0 volts
MRC:
The input relative humidity of the item,expressed in percent.AZTJ
Input Relative Humidity In Percent:
100.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Measurement range 0-100pct rh; single chip element with temperature and rh sensor, each element is individually calibrated with the calibration corrections stored on the chip
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum