رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Centrifugal Pump Unit
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
200.0 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
43.0 pounds per square inch gage
MRC:
The sum of the total discharge head and the total suction lift.AHYX
Total Head:
100.000 feet
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
3500.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
Centrifugal Pump Design:
Axial flow
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
1
MRC:
Indicates the type of suction produced by the impeller of the centrifugal pump.AHZG
Centrifugal Pump Impeller Suction Type:
Single