رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
18.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.125 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Flange
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Threaded
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Unable to decode
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACRX
Inlet Thread Direction:
Right-hand
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
12.000 inches
MRC:
Indicates the design type of the item.APGF
Design Type:
Dry
MRC:
Indicates the type of coolant used with the item.ARNA
Coolant Type:
Air
MRC:
The basic design of the muffler.ARND
Muffler Design:
Baffle
MRC:
The number of baffles included on the item.ARNE
Baffle Quantity:
3
MRC:
The number of tubes included on the item.ARNF
Tube Quantity:
1
MRC:
The physical configuration of the body.ARNG
Body Shape:
Round
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
Horizontal
MRC:
The location of the inlet.ARNJ
Inlet Location:
Centrally located in end section of body
MRC:
A measurement of the longest dimension of the inlet projection,in distinction from width.ARNK
Inlet Projection Length:
1.250 inches
MRC:
The physical configuration of the inlet flange.ARNL
Inlet Flange Shape:
Round
MRC:
Designates the thread diameter and quantity of threads per specific measurement scale.ARNW
Inlet Thread Size:
4-11-1/2
MRC:
A designation indicating the diameter-pitch and the number of threads per specific measurement scale applied to a series of specific diameters of an inlet.ARNX
Inlet Thread Series Designator:
Npt
MRC:
Indicates the location of the thread on the inlet.ARSP
Inlet Thread Location:
Internal
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Threaded
MRC:
The location of the outlet.ARTJ
Outlet Location:
Centrally located in end section ofbody
MRC:
A measurement of the longest dimension of the outlet projection,in distinction from width.ARTK
Outlet Projection Length:
4.625 inches
MRC:
Designates the thread diameter and number of threads per measurement scale of the outlet.ARTW
Outlet Thread Size:
4-11-1/2
MRC:
A designation indicating the diameter-pitch and the number of threads per measurement scale applied to a series of diameters of an outlet.ARTX
Outlet Thread Series Designator:
Npt
MRC:
The direction of the outlet thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ARTY
Outlet Thread Direction:
Right-hand
MRC:
Indicates the location of the thread on the outlet.ARTZ
Outlet Thread Location:
External
MRC:
The direction of the water outlet thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ARWB
Err Default:
Err default
MRC:
The direction of the water outlet thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ARWB
Water Outlet Thread Direction:
Right-hand
MRC:
A narrative description of the type of water outlet connection.ARXE
Err Default:
Err default
MRC:
A narrative description of the type of water outlet connection.ARXE
Water Outlet Connection Type:
Threaded
MRC:
The number of water outlets furnished with the item.ARXF
Err Default:
Err default
MRC:
The number of water outlets furnished with the item.ARXF
Water Outlet Quantity:
1
MRC:
The location of the water outlet.ARXG
Err Default:
Err default
MRC:
The location of the water outlet.ARXG
Water Outlet Location:
Located directly under exhaust outlet
MRC:
A measurement of the longest dimension of the water outlet projection,in distinction from width.ARXH
Err Default:
Err default
MRC:
A measurement of the longest dimension of the water outlet projection,in distinction from width.ARXH
Water Outlet Projection Length:
1.500 inches
MRC:
Designates the thread diameter and quantity of threads per specific measurement scale.ARXR
Err Default:
Err default
MRC:
Designates the thread diameter and quantity of threads per specific measurement scale.ARXR
Water Outlet Thread Size:
1-1/4-11-1/2
MRC:
A designation indicating the diameter-pitch and the number of threads per specific measurement scale applied to a series of a specific diameters of a water outlet.ARXS
Err Default:
Err default
MRC:
A designation indicating the diameter-pitch and the number of threads per specific measurement scale applied to a series of a specific diameters of a water outlet.ARXS
Water Outlet Thread Series Designator:
Npt
MRC:
Indicates the location/s/ of the water outlet on which the thread is located.ARXT
Err Default:
Err default
MRC:
Indicates the location/s/ of the water outlet on which the thread is located.ARXT
Water Outlet Thread Location:
External
MRC:
Indicates the type and number of nonconnection outlets used on the item.ARXY
Nonconnection Outlet Type And Quantity:
1 slotted err-100
MRC:
Indicates the type and number of nonconnection outlets used on the item.ARXY
Nonconnection Outlet Type And Quantity:
1 slotted
MRC:
Indicates the location/s/ of the nonconnection outlet on the item.ARXZ
Nonconnection Outlet Location:
Located on circle
MRC:
Designates the size of the nonconnection outlet included on the item.ARYA
Nonconnection Outlet Size:
2-1/2 in. Lg by 1-1/4 in. W
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Steel, sae 1010
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel comp 1010
MRC:
The specification,standard,or manufacturers reference,and the classification designation,such as class,condition,temper,and the like,that identifies the material.MDCL
Material Specification:
Sae 1010 assn standard single material response
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Zinc
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Zinc coated