C/o trailer mounted, towable and steerable; combination lifting & tiedown eyes; forklift channels; weight: 6, 000 lbs; hydraulic fluid is mil-h-5606; operating degrees: m40 to p160; hydraulic fluid conditioning: 1 per cent dissolved air ; 100 ppm water ; nas 1638, class 4 particles; four 20 in. Wheels; 60 psi pneumatic tire, 6x9, 10 ply; 66.5 in. Wheelbase; dim: 116 in. Lg; 79 in. W; 70 in. H
TXT
وصف:
Hydraulic System Comp Test Stand
MRC:
The amount of hydraulic fluid required to operate the item.AAYJ
Hydraulic Fluid Flow Rate:
60.0 gallons per minute
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
B-2 acft
MRC:
Indicates the type of drive for turning,rotating,or positioning the mechanism.AKCV
Drive Type:
Electric motor
MRC:
Indicates the designed use of the item.ALBY
Usage Design:
Aircraft hydraulic system
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
Not rated
MRC:
The source of power which drives the item.ATJK
Power Source:
Electric motor
MRC:
The maximum speed at which the item is designed to operate,expressed in revolutions per minute.ATPR
Maximum Speed Rating In Rpm:
Not rated
MRC:
An indication of whether or not an accumulator is included.AYJM
Accumulator:
Not included
MRC:
The pressure at which an item is designed to operate.BGST
Pressure Rating:
Between 0.0 pounds per square inch and 5000.0 pounds per square inch
MRC:
The maximum pressure at which the item is designed to operate.BJDW
Maximum Operating Pressure:
Not rated
MRC:
An indication of whether or not a design feature for testing engine driven hydraulic pumps is included.CGYK
Engine Driven Hydraulic Pump Testing Design Feature:
Included
MRC:
The rated flow capacity of the item.CGYL
Flow Capacity Rating:
Not rated
MRC:
An indication of whether or not a pressure manifold subcircuit(s) is included.CGYM
Pressure Manifold Subcircuit:
Not included
MRC:
The number of subcircuits provided and the maximum operating pressure of each subcircuit.CHGN
Subcircuit Quantity And Maximum Operating Pressure:
Two 5000 psi
MRC:
An indication of whether or not a filtering system is included.CHGQ
Filtering System:
Included
MRC:
An indication of whether or not a pressure and suction hose are included.CHGR
Pressure/suction Hose:
Not included
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
380.0 and 480.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
50.0 and 60.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Used to check the performance and operating characteristics of aircraft hydraulic systems
MRC:
A feature of the item of supply which must be specifically recorded when the reference number covers a range of items.ZZZY
Reference Number Differentiating Characteristics:
Source control item, repairable