رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Microcircuit, linear, - digital to analog converter, 8-bit
TXT
وصف:
Linear Microcircuit
MRC:
The maximum amount of electrical energy that can be expended by an item.AEHX
Maximum Power Dissipation Rating:
300.0 milliwatts
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
MRC:
The minimum and maximum temperatures at which an item can be stored without detrimental effect.AFJQ
Storage Tempurature Range:
-65.0/+150.0 degrees celsius
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
F-15e, f-16c/d; f100-pw-229 engine
MRC:
The chemical compound or mechanical mixture properties of which the inclosure is fabricated.CQSJ
Inclosure Material:
Ceramic
MRC:
Indicates the physical configuration of the inclosure.CQSZ
Inclosure Configuration:
Dual-in-line
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The basic purpose and number of functions of the device,modified by its intended use.CSSL
Design Function And Quantity:
1 converter, digital to analog
MRC:
The value of the voltage applied and type of specific electrical characteristic for which the item is designed.CZEN
Voltage Rating And Type Per Characteristic:
-18.0 volts input and 18.0 volts input
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Sensitive electronic device
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
96906-mil-std-883 standard (includes industry or association standards, individual manufactureer standards, etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
18 printed circuit