رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Safety Relief Valve
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk
MRC:
Indicates the type of housing on the item that accommodates the stem packing or spring.ADSR
Bonnet Type:
Inside spring
MRC:
The means by which the bonnet is attached to the item.ADST
Bonnet Attachment Method:
Bolted
MRC:
The means of closing the item when inlet pressure decreases.ADSU
Disk Loading Method:
Spring
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
150.0 degrees fahrenheit single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Socket (tube) err-100
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Automatic
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded internal tube all ends
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
400.0 pounds per square inch single response
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
1.000 inches all ends
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy bodystainless steel flow control devicesteel seatstainless steel stem
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Water, salt single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Err-090
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.TMQY
Furnished Items And Quantity:
1 lever