رقم الجزء
تجريد
صلاحيه
UOM
NIIN
رقم الجزء:
dpl3301t242416
معلومات الجزء
Internal bore polytetrafluoroethylene (pfte) coat ed to first groove
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Swaged w/ grooves (tube) all ends
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
2.875 inches 3rd end
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
3.590 inches 1st end
MRC:
A measurement of the longest dimension of the leg,in distinction from width.AHSJ
Leg Length:
3.590 inches 2nd end
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Unthreaded internal tube all ends
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
2000.0 pounds per square inch 3rd response
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
500.0 pounds per square inch 1st response
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
500.0 pounds per square inch 2nd response
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
1.000 inches 3rd end
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
1.500 inches 1st end
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
1.500 inches 2nd end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.032 inches 1st end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.032 inches 2nd end
MRC:
The nominal thickness of the tubing wall for which designed as taken from the inside surface to the nearest outer surface.CWFK
Tubing Wall Thickness For Which Designed:
0.036 inches 3rd end
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Titanium alloy uns r54520