رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
A measurement of the extent of threads,including incomplete threads,along a line parallel to the longitudinal axis.AASA
Thread Length:
0.375 inches single mounting facility
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.125 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.812 inches
First Flat Length:
0.375 inches single actuator
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.250 inches single actuator
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
1.562 inches single actuator
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
2
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
1.250 inches single mounting facility
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing single mounting facility
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.375 inches single mounting facility
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
125.0 dc at sea level
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
250.0 ac at sea level
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line single mounting facility
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
2 single actuator
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, nonparallel flatted single actuator
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Threaded stud
MRC:
The increments of angular rotation that the switch actuator moves between adjacent index positions.CSLC
Switch Actuator Positioning Increment:
50.0 degrees single actuator
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
12.0 amperes resistive load ac at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
6.0 amperes resistive load dc at sea level
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
In-line, cam actuated
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unef single mounting facility