رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Electrical Dummy Load
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.AAQF
Ambient Tempurature In Deg Celsius At Full Rated Power:
-40.0 and 65.0
MRC:
The range of complete cyclic changes,per unit of time,for which an item is rated.AFGQ
Frequency Range Rating:
+14.000/+14.200 gigahertz
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Radar threat emitter an/mst-t1
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.15
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
30.000 kilowatts peak and 2.000 kilowatts average
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Waveguide flange
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
All positions
MRC:
The nominal exerted outward force,per unit of area,for which the item is designed.AWNC
Internal Operating Pressure:
5.0 pounds per square inch gage
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Forced air
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Waveguide mounted