رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
9.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.870 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.200 inches
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 2nd operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
210.0 ac pounds per hour dry 1st operating power rqmt and 250.0 ac pounds per hour with retaining chain 1st operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
105.0 ac pounds per hour dry 2nd operating power rqmt and 125.0 ac pounds per hour with retaining chain 2nd operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
12.0 dc volts multiple power outputs w/identical ratings and 15.0 dc volts multiple power outputs w/identical ratings
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 1st operating power rqmt and 63.0 hertz 1st operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 2nd operating power rqmt and 63.0 hertz 2nd operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+40.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
1 multiple power outputs w/identical ratings
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Voltage adjustment multiple power outputs w/identical ratings
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
2.8 dc amperes multiple power outputs w/identical ratings and 3.0 dc amperes multiple power outputs w/identical ratings
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 multiple power outputs w/identical ratings
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Solder stud multiple power outputs w/identical ratings