رقم الجزء:
evt317-5do-02f-q
معلومات الجزء
Pneumatic control valve
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Poppet
MRC:
The position of the moving member/s/ controlling flow through the valve with the solenoid in the de-energized position.ADSK
Flow Control Device Normal Operation Position:
Open
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
50.0 degrees celsius single response
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.25 inches all ends
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
24.0 dc
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
G 1/4 3/2 spring/solenoid stand-alone; 1/ 4 in ports, tapered threads; standard din 43650 electrical connection; push button manual override; surge voltage protection; coils may be orientated at 90? Increments; flow rate: 687.05nl/min; solenoid power consumption: 6w;
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy body
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Vacuum single response