رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Furnished with cga type cg-7 pressure relief device set at 450 psig; with cga outlet connection no 660 wiht dual controls and single outlet port; inlet for liquid withdrawal shall be fitted (silver brazed) with 3/8 in.O.D. By 2in. Lg copper did tube with retaining rib
TXT
وصف:
Gas Cylinder Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Brass
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Angle give "adqm" and "adqn" only if flanged one or two ends
MRC:
Items furnished as accessories which are not specified elsewhere.ABFF
Furnished Items:
Safety device
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ABJH
Tempurature Rating:
70.0 degrees fahrenheit
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Refrigerant
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded external gas cylinder
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Gasket seal
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Threaded external gas cylinder
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Plain
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACMS
Second End Thread Direction:
Right-hand
MRC:
The means used to change the valve opening to control the flow of fluids or gases.ADQW
Valve Operation Method:
Wheel
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The minimum and maximum pitch diameter limits of a straight screw thread.ADRN
First End Thread Pitch Diameters:
+0.9796/+0.9836 inches
MRC:
The minimum and maximum pitch diameter limits of a straight screw thread.ADRP
Second End Thread Pitch Diameters:
+0.9677/+1.0570 inches
MRC:
A designator distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CQMM
First End Thread Series Designator:
Ngo
MRC:
The designation which is used for the purpose of general identification of the nominal thread size.CQYM
First End Thread Size:
1.030 inches
MRC:
The designation which is used for the purpose of general identification of the nominal thread size.CRNB
Second End Thread Size:
0.750 inches
MRC:
A designator distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CRPF
Second End Thread Series Designator:
Ngt