رقم الجزء
تجريد
صلاحيه
UOM
NIIN
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
11.000 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
17.156 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
7.062 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc input
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
35000.0 feet
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Totally enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Fixed base
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Commercial
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Horizontal mounting position
MRC:
The nominal center to center distance between the mounting facilities parallel to the length.CWDT
Center To Center Distance Between Mounting Facilities Parallel To Length:
7.438 inches
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
55.0 ambient degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
8000.0 single full load
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
6.000 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
115.0 line to line single output
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
27.5 line to neutral single input
MRC:
The number of alternating current phases.FAAZ
Phase:
Single output
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 output