رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Extractor Post Fuseholder
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Plastic
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Panel mounted type
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dripproof
MRC:
The element,compound,or mixture of which the contact/s/ is fabricated,excluding any surface treatment.AFRG
Contact Material:
Copper
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the contact surface.AFRH
Contact Surface Treatment:
Any acceptable
MRC:
The means in which the item signals the interruption of a circuit.AFXH
Interruption Indicator Method:
Neon lamp
MRC:
The number of fuses the item is designed to accommodate /including spares/.AGUE
Fuse Accommodation Quantity:
1
MRC:
A measurement of the longest dimension of a fuse the item can accommodate.AGUJ
Accommodated Fuse Length:
0.460 inches
MRC:
The length of a straight line which passes through the center of the accommodated ferrule,and terminates at the circumference.AGUK
Accommodated Ferrule Diameter:
0.235 inches
MRC:
The rated ohmic value of the resistor/s/ furnished with the item.AGUN
Resistor Rating:
680.0 ohms
MRC:
The amount of electrical current the item is designed to carry,expressed in amperes.CQJL
Current Carrying Rating In Amps:
5.0
MRC:
Indicates the type of fuse terminations which the item will accommodate.CSNM
Fuse Terminal Type Accommodated:
Pin
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
45.0
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-f-19207/28 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
3 tab, solder lug