رقم الجزء
تجريد
صلاحيه
UOM
NIIN
معلومات الجزء
Incubator bacterological: lrg 115/230v 60hz ac
TXT
وصف:
Bacteriological Incubator
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
24.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
40.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
53.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
Between 50.0 hertz and 60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
22.000 inches
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
20.000 inches
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
24.000 inches
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 110.0 volts and 120.0 volts
MRC:
The amount of electrical energy that can be dissipated.ANPT
Power Rating:
1000.0 watts
MRC:
Indicates the type of control.AQZF
Control Type:
Temperature control dial or thermometer
MRC:
The minimum and maximum operating temperatures at which the item is rated,expressed in degrees celsius.ASQJ
Operating Tempurature Range In Deg Celsius:
+20.0/+65.0
MRC:
The heat source for which the item is designed.AZZH
Heat Source For Which Designed:
Integral
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
An indication of whether or not the item is provided with a water jacket.BGXH
Water Jacket:
Not provided
MRC:
The number of shelves furnished with the item.BGZL
Shelf Quantity:
12
MRC:
An indication of whether or not the shelf(ves) is adjustable.BGZM
Shelf Adjustability:
Adjustable
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Gravity
MRC:
An indication of whether or not an insulated cabinet is provided.BLST
Insulated Cabinet:
Provided
MRC:
The element,compound,or mixture of which the shelf is fabricated,excluding any surface treatment.BPYK
Shelf Material:
Steel, stainless
MRC:
The element,compound,or mixture of which the cabinet outer wall is fabricated,excluding any surface treatment.BQMH
Cabinet Outer Wall Material:
Steel
MRC:
The element,compound,or mixture of which the cabinet inner wall is fabricated,excluding any surface treatment.BQMJ
Cabinet Inner Wall Material:
Steel, stainless
MRC:
The number of outer doors included.BQMN
Outer Door Quantity:
2
MRC:
An indication of whether or not an outer door insulation feature is included.BQMR
Outer Door Insulation Feature:
Not included
MRC:
The number of inner doors included.BQMS
Inner Door Quantity:
2
MRC:
The element,compound,or mixture of which the inner door is fabricated,excluding any surface treatment.BQMT
Inner Door Material:
Glass
MRC:
The means of attaching the inner door.BQMW
Inner Door Mounting Method:
Hinge
MRC:
An indication of whether or not a vacuum chamber is included.BQWN
Vacuum Chamber:
Not included
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
1/4 in. Glass inner doors, dual chambers