رقم الجزء
تجريد
صلاحيه
UOM
NIIN
TXT
وصف:
Waveguide Assembly
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b all flanges second connection facility
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand all flanges second connection facility
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
0.2225 inches first flange and 0.2255 inches first flange
Flange Inside Width:
0.2225 inches second flange and 0.2255 inches second flange
Flange Inside Height:
0.1105 inches first flange and 0.1135 inches first flange
Flange Inside Height:
0.1105 inches second flange and 0.1135 inches second flange
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the outside circumference.AHTC
Flange Outside Diameter:
1.125 inches first flange and 1.127 inches first flange
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the outside circumference.AHTC
Flange Outside Diameter:
1.125 inches second flange and 1.127 inches second flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.245 inches first flange and 0.255 inches first flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.245 inches second flange and 0.255 inches second flange
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.116 inches all flanges first connection facility and 0.119 inches all flanges first connection facility
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.02
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.30
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.112 inches all flanges second connection facility
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 threaded hole all flanges second connection facility
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 unthreaded hole all flanges first connection facility
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type first flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type second flange
Waveguide Length:
1.375 inches
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Rigid single tubing segment
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Straight type
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc all flanges second connection facility